GWPR-SRI Reactor Integrated Differential Protection Relay

Functions(ANSI) 87R 50/50N 51/51N 46 59 27 49
Product Desc

GWPR-SRI Reactor Integrated Differential Protection Relay (Brand: GoWatron) is suitable for reactor protection and measurement & control at voltage levels of 132 kV, 66 kV, 33 kV, and 11 kV. It uses a 32-bit high-performance microcontroller integrating DSP and FPU, providing comprehensive protection, measurement, control, communication, and time synchronisation functions. The GWPR-SRI Reactor Integrated Differential Protection Relay features flexible hardware configuration and high immunity to electromagnetic interference, meeting the diverse requirements of power systems for reactor protection.

  • Communication Interfaces: 2 Ethernet ports, 2 RS-485 ports (the second RS-485 port is multiplexed with the time synchronisation port; communication and time synchronisation are selected via configuration)
  • Communication Protocols: IEC 60870-5-104, IEC 60870-5-103, IEC 61850 (optional)
  • Time Synchronisation Methods: Communication message-based time synchronisation, SNTP time synchronisation, and IRIG-B time synchronisation
Accuracy
Accuracy
≤ 0.2%
Quick Response
Quick Response
≤ 100ms
Reliable Protection
Reliable Protection
Comprehensive Protection
Quality Assurance
Quality Assurance
ISO 9001 Certified
Technical Support
Technical Support
24/7 Expert Support
Fast Delivery
Fast Delivery
Global Shipping
Warranty
Warranty
2-Year Warranty

1. Product Introduction

  • The GWPR-SRI Reactor Integrated Differential Protection Relay is a reactor integrated differential protection relay developed by GoWatron, suitable for reactor protection and measurement & control at voltage levels of 132 kV, 66 kV, 33 kV, and 11 kV. The GWPR-SRI Reactor Integrated Differential Protection Relay adopts a full-panel, fully enclosed chassis with isolation between power/control circuits and low-level signal circuits, and corresponding anti-interference measures are taken in both software and hardware design, meeting relevant electromagnetic compatibility standards. The GWPR-SRI Reactor Integrated Differential Protection Relay provides complete protection functions, with each protection element designed in a modular manner, mutually independent and flexibly configurable, featuring a user-friendly human-machine interface and convenient on-site testing functions.
  • The GWPR-SRI Reactor Integrated Differential Protection Relay supports 21 active binary inputs, 11 protection outputs, 2 signal outputs, and 1 device power-loss output. It is equipped with dual Ethernet interfaces, RS-485 serial communication interfaces, and an IRIG-B time synchronisation interface. The GWPR-SRI Reactor Integrated Differential Protection Relay uses independent 16-bit analogue-to-digital conversion for high-precision sampling, combined with an algorithm for filtering anomalous samples to improve the anti-interference capability of AC signal acquisition. It also features fault recording, event logging, and communication with the supervisory system, facilitating on-site commissioning, operation, and maintenance.

2. Product Functions

Differential Protection

  • (ANSI 87R) Instantaneous Differential Protection (Trip) — Fast differential protection for internal reactor faults
  • (ANSI 87R) Percentage-Restrained Differential Protection (Trip) — Percentage restrained differential protection
  • CT Circuit Supervision (Immediate indication with a time-delayed alarm) — CT secondary circuit abnormality supervision
  • Differential Current High Alarm — Differential current over-limit supervision

Overcurrent Protection

  • (ANSI 50/51) Three-stage Definite-Time Overcurrent Protection (Trip, with configurable directional and composite voltage supervision) — Definite-time overcurrent protection; when directional supervision is enabled, the protection operates as directional overcurrent protection (ANSI 67)
  • (ANSI 51) Inverse-Time Overcurrent Protection (Trip, selectable among standard inverse, very inverse, and extremely inverse, with configurable directional and composite voltage supervision) — Inverse-time overcurrent protection; when directional supervision is enabled, the protection operates as directional overcurrent protection (ANSI 67)
  • (ANSI 49) Overload Protection (Alarm/Trip selectable) — Reactor overload supervision and protection
  • (ANSI 46) Negative-Sequence Overcurrent Stage I (Trip) — Negative-sequence current/phase current unbalance protection
  • (ANSI 46) Negative-Sequence Overcurrent Stage II (Alarm/Trip selectable)
  • (ANSI 50N/51N) Zero-Sequence Overcurrent Stages I & II (Trip) — Zero-sequence definite-time overcurrent protection
  • (ANSI 50N/51N) Zero-Sequence Overcurrent Stage III (Alarm/Trip selectable)
  • (ANSI 51N) Zero-Sequence Inverse-Time Overcurrent Protection (Trip)
  • (ANSI 50/51) Neutral-End Overcurrent Stages I & II (Trip, with configurable composite voltage supervision) — Definite-time overcurrent protection for reactor neutral-end current

Voltage Protection

  • (ANSI 59) Overvoltage Protection (Trip) — Overvoltage protection
  • (ANSI 27) Undervoltage Protection (Trip) — Undervoltage protection
  • System Power Loss Protection (Alarm/Trip selectable) — Identifies system power-loss status based on specified voltage, current, and status criteria
  • PT Circuit Supervision (Alarm) — Voltage transformer secondary circuit abnormality supervision

Other Protection

  • Control Circuit Disconnection Supervision (Alarm) — Circuit breaker control circuit abnormality supervision
  • 6 Channels of Non-Electrical Protection (Alarm/Trip selectable) — Receives contact signals from reactor body protection

Measurement and Control Functions

  • AC Signals: Voltages Ua, Ub, Uc, Uab, Ubc, Uca; Currents Ia, Ib, Ic, ia1, ib1, ic1, ia2, ib2, ic2, i30
  • Power: P, Q, COSΦ
  • Energy: EP+, EP-, EQ+, EQ-
  • Supports 21 active binary inputs (AC/DC 220 V, DC 100 V, or DC 48 V; please specify when ordering)
  • Supports 11 protection outputs, 2 signal outputs, and 1 device power-loss output

3. Product Application Scenarios

  • The GWPR-SRI Reactor Integrated Differential Protection Relay is suitable for the following scenarios:
  • Reactor protection and measurement & control at voltage levels of 132 kV, 66 kV, 33 kV, and 11 kV
  • Reactor protection in substations, power plants, industrial and mining enterprises, and other power systems
  • Applications requiring multiple protection functions such as differential protection, overcurrent protection, zero-sequence protection, and overvoltage/undervoltage protection
  • Power automation systems requiring integrated measurement & control, communication networking, and time synchronisation
  • Smart substations requiring flexible protection function configuration and support for IEC 60870-5-104, IEC 60870-5-103, and IEC 61850 (optional) communication protocols
  • Applications requiring real-time monitoring, fault recording, and event logging of reactor operating status
  • Operation and maintenance scenarios requiring on-site commissioning, local testing, and report printing
REQUEST QUOTE(RFQ)
Please fill in the form below and we will get back to you within 24 hours.
Quote Form

1.PROJECT INFORMATION

2. PRODUCTS FOR QUOTATION


3. RFQ SCHEDULE

4. TECHNICAL DOCUMENTS UPLOAD

Supported formats: PDF, Word, Excel, CAD, ZIP, RAR, JPG, PNG
Max file size: 50MB per file | Max total size: 200MB


5. PROJECT REQUIREMENTS


6.CONTACT INFORMATION


6. VERIFICATION


GWPR-RI Reactor Integrated Differential Protection Relay
GWPR-RI Reactor Integrated Differential Protection Relay – Left View
GWPR-RI Reactor Integrated Differential Protection Relay – Right View